6.1.1.1.1. Accessing the Voltage Sensor in the Core Access Mode when MD[1:0] is not Equal to 2'b11
The following timing diagram shows the IP core timing to access the voltage sensor when MD[1:0] is not equal to 2'b11.
Figure 8. Timing Diagram when MD[1:0] is not Equal to 2'b11
- A low-to-high transition on the corectl signal enables the core access mode.
Wait for a minimum of two clock cycles before proceeding to step 2.
- De-asserting the reset signal releases the voltage sensor from the reset state.
Wait for a minimum two clock cycles before proceeding to step 3.
- Configure the voltage sensor by writing the configuration registers and asserting the coreconfig signal for eight clock cycles. The configuration register access mode is 8 bits and configuration data is shifted in serially.
- The coreconfig signal going low indicates the start of the conversion based on the configuration defined in the configuration register.
- Poll the eoc and eos status signals to check if conversion for the first channel defined by MD[1:0] is complete. Latch the output data on the dataout[5:0] signal at the falling edge of the eoc signal.
- Poll the eoc and eos status signals to check if conversion for the subsequent channels defined by MD[1:0] are complete. Latch the output data on the dataout[5:0] signal at the falling edge of the eoc signal.
- Repeat step 6 until the eos signal is asserted, indicating the completion of the conversion of one cycle on the channels specified by MD[1:0].
- Both the eoc and eos signals are asserted on the same clock cycle when the voltage sensor completes the conversion for the last channel.
- You can only interrupt the operation of the voltage sensor by writing into the configuration register after one cycle of the eos signal completes.
- When the sequence completes, and if the corectl and reset signals remain unchanged, the conversion repeats the same sequence again until corectl is 0 and reset is 1. If you want to measure other sequences, repeat step 2 to step 7.