5.2. Setting Up the SEU Mitigation Features

Perform these steps to set up the Agilex™ 5 SEU detection, enable internal and external scrubbing, enable sensitivity map generation, and allow fault injection.
  1. From the Quartus® Prime menu, select Assignments > Device.
  2. In the Device window, click Device and Pin Options
  3. In the Device and Pin Options window, navigate to Error Detection CRC.
  4. Specify the following options:
    Setting Description
    Enable error detection check Turn on to enable the error detection feature. This option is required for sensitivity processing and fault injection, or if you want to observe the SEU_ERROR pin behavior.
    Minimum SEU interval Enter a value of 0 to 10000 milliseconds to set the minimum time between two checks of the same bit. To check as frequently as possible, enter 0.

    The actual minimum interval may be higher than the value you specify. The System Message window reports the actual value when you select a generated .sof file as an input file in the Quartus® Prime Programming File Generator or Programmer.

    Note: To determine the minimum SEU detection interval of the device, set Minimum SEU interval to 0 or any value that is lower than the actual minimum interval.
    Enable internal scrubbing Turn on to enable the error correction feature. You require this option for sensitivity processing.
    Generate SEU sensitivity map file (.smh) Turn on to generate the .smh file. You require this option for sensitivity processing.
    Allow SEU fault injection Turn on to enable injecting fault using the Fault Injection Debugger.
    Enable external scrubbing Turn on to generate a .sof file with hashes of CRAM content for all sectors within the .sof option.
  5. Click OK.