Intel® Arria® 10 Core Fabric and General Purpose I/Os Handbook

ID 683461
Date 10/25/2023
Public
Document Table of Contents

5.5.5.1. Single-Ended I/O Termination

Voltage-referenced I/O standards require an input VREF and a termination voltage (VTT). The reference voltage of the receiving device tracks the termination voltage of the transmitting device.

The supported I/O standards such as SSTL-12, SSTL-125, SSTL-135, and SSTL-15 typically do not require external board termination.

Intel recommends that you use OCT with these I/O standards to save board space and cost. OCT reduces the number of external termination resistors used.

Note: You cannot use RS and RT OCT simultaneously. For more information, refer to the related information.
Figure 90. SSTL I/O Standard TerminationThis figure shows the details of SSTL I/O termination on Arria® 10 devices.


Figure 91. HSTL I/O Standard TerminationThis figure shows the details of HSTL I/O termination on the Arria® 10 devices.


Figure 92. POD I/O Standard TerminationThis figure shows the details of POD I/O termination on the Arria® 10 devices.