Article ID: 000086899 Content Type: Error Messages Last Reviewed: 05/13/2019

Internal Error: Sub-system: SIN, File: /quartus/tsm/sin/sin_micro_tnodes_dag.cpp, Line: 978

Environment

  • Intel® Quartus® Prime Pro Edition
  • External Memory Interfaces Intel® Stratix® 10 FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Software version 17.1 and earlier, you may see this internal error when compiling an Intel Stratix® 10 project which contains an External Memory Interfaces Intel Stratix 10 FPGA IP and the following qsf assignment:

    set_global_assignment -name ENABLE_SMART_VOLTAGE_ID ON

    Internal Error: Sub-system: SIN, File: /quartus/tsm/sin/sin_micro_tnodes_dag.cpp, Line: 978
    Problem encountered while reading the specified SIN_MICRO_TNODES_DAG from disk [17.1.2/304/linux64/quartus/common/devinfo/14nm/ddb_nadder_emif_fls_vid2]

    This internal error may also be seen when migrating a project to Quartus Prime Pro Software version 18.0.

    Resolution

    The ENABLE_SMART_VOLTAGE_ID assignment set to ON is not supported for Stratix 10 FPGA devices. Change the qsf assignment to
    set_global_assignment -name ENABLE_SMART_VOLTAGE_ID OFF

    Stratix 10 VID parameters are set up in Assignments > Device > Device and Pin Options > Power Management and VID

    In the Quartus Prime Pro Software version 18.0, the SmartVoltage ID setting is greyed out in Settings > Operating Settings and Conditions

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs