Article ID: 000085615 Content Type: Troubleshooting Last Reviewed: 09/11/2012

Is there a known issue with the ALTREMOTE_UPDATE megafunction for Stratix V and Arria V devices?

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Yes, there is a known issue with the ALTREMOTE_UPDATE megafunction for Stratix® V and Arria® V devices. The logical atom definition for stratixv_rublock and arriav_rublock in the WYSIWYG atom for Stratix V and Arria V devices were defined incorrectly. Thus, the megafunction will fail to function correctly in these devices.

    Resolution

    This issue has been fixed in the Quartus® II software version 11.1SP2 or later.

    If you are using Quartus II software version prior to 11.1SP2, recompile your design using Quartus II software version 11.1SP2 or later.

    Related Products

    This article applies to 8 products

    Arria® V GX FPGA
    Arria® V GT FPGA
    Arria® V ST SoC FPGA
    Arria® V SX SoC FPGA
    Stratix® V E FPGA
    Stratix® V GS FPGA
    Stratix® V GX FPGA
    Stratix® V GT FPGA