Due to a problem in the Intel® Quartus® Prime software version 19.1 and earlier, the design example testbench for E-Tile Hard IP for Ethernet Intel® Stratix® 10 FPGA IP variant with “AN/LT” and “PCS_only” options selected will not complete.
To work around this problem, perform the following steps:
1.) Navigate to the alt_ehip3_0_example_design/example_testbench directory
2.) Open the “basic_avl_tb_top.sv” file
3.) Change line 461 FROM:
#5000 i_reconfig_clk = ~i_reconfig_clk;
TO:
#500 i_reconfig_clk = ~i_reconfig_clk;
4.) Rerun simulation
This problem is scheduled to be fixed in a future release of the Intel® Quartus® Prime software.