Article ID: 000078144 Content Type: Error Messages Last Reviewed: 09/11/2012

Error (175005): Could not find a location with: VCCPD of 2.5V

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Quartus® II software versions 11.1 SP2 and earlier, designs targeting Stratix® V devices will generate this error message if you assign a 2.5 V I/O standard input into an I/O bank that is powered by 3.0 V.

    Resolution

    To work around this problem until it is fixed in the Quartus II software, change the input I/O standard from 2.5 V to 3.0 V. When the fixed version of the Quartus II software is available, change the input I/O standard back to 2.5 V and recompile your project.

    This problem is fixed beginning with the Quartus II software version 12.0.

    Related Products

    This article applies to 4 products

    Stratix® V E FPGA
    Stratix® V GX FPGA
    Stratix® V GT FPGA
    Stratix® V GS FPGA