Description
You may encounter the following Quartus® II errors if you try to recompile the Stratix® IV and V Transceiver Toolkit version 12.1 design examples with Quartus II 13.0:
- Error (12252): Link_test_sopc_sys.clk.clk_reset/checker_0.csr_clk_reset: Missing connection end (try "Remove Dangling Connections")
- Error (12252): Checker_0_csr_slave_translator.avalon_anti_slave_0: Cannot connect checker_0_csr_slave_translator.reset because checker_0.reset is not connected
- Error (12077): Node instance "auto_hub" instantiated with unknown parameter "BROADCAST_FEATURE"
Resolution
Perform the following steps in Qsys to remove the errors:
- Click "Remove Dangling Connections".
- Provide resets to the generator and checker blocks.
- Remove the files with prefix "sld_*" from the Megafunctions™ folder in the design example.