Article ID: 000077327 Content Type: Troubleshooting Last Reviewed: 06/13/2019

What are the PMA Adaptation Status Codes in an Intel® Stratix® 10 E-Tile Device Native PHY IP?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    In an Intel® Stratix® 10 E-Tile device Native PHY IP, the PMA adaptation status codes report the associated calibration being executed. The coding is as follows:

    • Initial adaptation done => 0x80
    • Initial adaptation in progress => 0x91
    • One-time continuous adaptation in progress = 0xa2
    • One-time continuous adaptation done => 0x80
    • Running continuous adaptation => 0xe2

    You should monitor the PMA AVMM registers 0x207 for 0x80 which means that a new message was received and the PMA AVMM register 0x204 for the status codes indicated above.

    Related Products

    This article applies to 2 products

    Intel® Stratix® 10 TX FPGA
    Intel® Stratix® 10 MX FPGA